2 INFORM Explanation
FS100 2.1 I/O Instructions : ANTOUT
2-23
2. ON/OFF
When an AT# (anticipation output number) is selected from the table in
part 1 of this Explanation, add the following tag.
SUPPLE
-MENT
Settings for the anticipation output signal
Set the number of the output signal for the anticipation output in the ANTICIPATION OUT-
PUT display.
A. OT OUTPUT (Setting range: 1 to 1024)
Allocate the number of the general-purpose output whose signal timing is to be adjusted
to AT NO. 1 to 32.
B. ON TIME (Setting range: -32.768 to 32.767 seconds)
Set the delay/advance time for turning ON the signal.
C. OFF TIME (Setting range: -32.768 to 32.767 seconds)
Set the delay/advance time for turning OFF the signal.
D. OG OUTPUT (Setting range: 1 to 128)
Allocate the group number of the general-purpose output whose signal timing is to be
adjusted to AG NO. 1 and 16.
E. TIME (Setting range: -32.768 to 32.767 seconds)
Set the delay/advance time for carrying out the group output.
A
B
D
C
E
No. Tag Explanation Note
3 ON/OFF Specifies the ON/OFF status of the signal whose output
timing is adjusted.