EasyManuals Logo

YASKAWA G7 Series User Manual

YASKAWA G7 Series
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #347 background imageLoading...
Page #347 background image
Individual Functions
6-129
Related Parameters
* 1. Factory settings will change depending on the control mode.
* 2. The setting range becomes 1.00 to 300.0 when using controls modes Flux Vector or Open Loop Vector 2.
Parameter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Operation
Control Methods
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vector
Open
Loop
Vector
2
C5-01
ASR
Proportional
Gain 1
Sets the proportional gain of the speed
control loop (ASR)
0.00 to
300.00
*2
20.00
*1
Yes No A No A A
ASR P Gain
1
C5-02
ASR Integral
Time 1
Sets the integral time of the speed control
loop (ASR)
0.000
to
10.000
0.500
sec
*1
Yes No A No A A
ASR I Time
1
C5-03
ASR
Proportional
Gain 2
Sets the speed control gain 2 and integral
time 2 of the speed control loop (ASR).
Note: Adjustment is not normally required.
0.00
to
300.00
*2
20.00
*1
Yes No A No A A
ASR P Gain
2
C5-04
ASR Integral
Time 2
0.000
to
10.000
0.500
sec
*1
Yes No A No A A
ASR I Time
2
C5-05
ASR Limit Sets the upper limit for the speed control
loop (ASR) as a percentage of the
maximum output frequency (E1-04).
0.0
to
20.0
5.0% No No A No No No
ASR Limit
C5-06
ASR Primary
Delay Time
Constant
Sets the filter time constant for the time
from the speed loop to the torque command
output.
0.000
to
0.500
0.004
*1
No No No No A A
ASR Delay
Time
C5-07
ASR Gain
Switching
Frequency
Sets the frequency for switching between
Proportional Gain 1, 2 and Integral Time 1,
2.
0.0
to
400.0
0.0 No No No No A A
ASR Gain
SW Freq
C5-08
ASR Integral
Limit
Sets the ASR integral upper limit and rated
load as a percentage of maximum output
frequency (E1-04).
0 to 400 400 No No No No A A
ASR I Limit
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA G7 Series and is the answer not in the manual?

YASKAWA G7 Series Specifications

General IconGeneral
SeriesG7
Frequency50/60 Hz
Output VoltageMatches Input Voltage
Control MethodV/f Control
Overload Capacity150% for 60 seconds
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
CommunicationRS-485, Modbus, DeviceNet, Profibus, Ethernet
SafetySafe Torque Off (STO)
Operating Temperature-10°C to 50°C
Humidity5% to 95% (non-condensing)
Cooling MethodFan Cooled
Enclosure RatingIP20
Storage Temperature-20°C to 65°C