6-146
During the copy operation, errors may occur. If an error is displayed, press any key to cancel the error display
and return to the 03-01 display.
Error displays and their meanings are shown below. (Refer to Chapter 7 Errors when Using Digital Operator
Copy Function.)
5 Change the set value to 2 using the Increment Key.
6 Set the changed data using the DATA/ENTER Key. The COPY function will start.
7 If the COPY function ends normally, End is displayed on the Digital Operator.
8 The display returns to o3-01 when a key is pressed.
Error Display Meaning
Drive product code and Drive software number are different.
Drive capacity with which you are trying to copy, and the Drive capacity stored in the
Digital Operator are different.
The Drive control method in which you are trying to copy, and the Drive control method
stored in the Digital Operator are different.
Comparison between the parameter written to the Drive and the parameter in the Digital
Operator shows they are different.
After copying has ended, comparison between the sum value of the Drive parameter area
and the sum value of the Digital Operator parameter area shows they are different.
Table 6.2 COPY Function Procedure
Step
No.
Digital Operator Display Explanation
Copy Funtion Sel
-ADV-
o3-01= 2
OPINV WRITE
*0*
COPY
-ADV-
OPINV
COPYING
COPY
-ADV-
COPY COMPLETE
Copy Funtion Sel
-ADV-
o3 - 01=0
COPY SELECT
*0*
CPE
ID UNMATCH
VAE
INV. KVA UNMATC
CRE
CONTROL UNMATCH
CYE
COPY ERROR
CSE
SUM CHECK ERROR
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA G7 Series and is the answer not in the manual?

YASKAWA G7 Series Specifications

General IconGeneral
SeriesG7
Frequency50/60 Hz
Output VoltageMatches Input Voltage
Control MethodV/f Control
Overload Capacity150% for 60 seconds
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
CommunicationRS-485, Modbus, DeviceNet, Profibus, Ethernet
SafetySafe Torque Off (STO)
Operating Temperature-10°C to 50°C
Humidity5% to 95% (non-condensing)
Cooling MethodFan Cooled
Enclosure RatingIP20
Storage Temperature-20°C to 65°C