Parameter List
1
1.21 Defaults by Drive Model and Duty Rating ND/HD
YASKAWA TOEPYAIGA8002B GA800 Drive Programming 135
No.
*1
Name Unit Default
- Drive Model - 2012 2018 2021 2030
C6-01
Normal /
Heavy Duty
Selection
-
HD ND HD ND HD ND HD ND
0 1 0 1 0 1 0 1
o2-04
Drive Model
(KVA)
Selection
Hex. 66 67 68 6A
E2-11
(E4-11, E5-
02)
Motor Rated
Power
HP (kW)
3
(2.2)
4
(3.0)
4
(3.0)
5
(3.7)
5
(3.7)
7.5
(5.5)
7.5
(5.5)
10
(7.5)
C5-17
(C5-37)
Motor Inertia kgm
2
0.0088 0.0158 0.0158 0.0158 0.0158 0.0255 0.026 0.037
C6-02
Carrier
Frequency
Selection
- 1 7 1 7 1 7 1 7
E2-01
(E4-01)
Motor Rated
Current (FLA)
A 8.5 11.4 11.4 14 14 19.6 19.6 26.6
E2-02
(E4-02)
Motor Rated
Slip
Hz 2.9 2.7 2.7 2.73 2.73 1.5 1.5 1.3
E2-03
(E4-03)
Motor No-
Load Current
A 3 3.7 3.7 4.5 4.5 5.1 5.1 8
E2-05
(E4-05)
Motor Line-to-
Line
Resistance
Ω 1.601 1.034 1.034 0.771 0.771 0.399 0.399 0.288
E2-06
(E4-06)
Motor
Leakage
Inductance
% 18.4 19 19 19.6 19.6 18.2 18.2 15.5
E2-10
(E4-10)
Motor Iron
Loss
W 77 91 91 112 112 172 172 262
E5-01
PM Motor
Code Selection
- FFFF FFFF FFFF FFFF FFFF FFFF FFFF FFFF
L2-02
Power Loss
Ride Through
Time
s 0.5 0.5 1 1 1 1 1 1
L2-03
Minimum
Baseblock
Time
s 0.5 0.5 0.5 0.6 0.6 0.7 0.7 0.8
L2-04
Powerloss V/f
Recovery
Ramp Time
s 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
L2-05
Undervoltage
Detection Lvl
(Uv1)
- 190 190 190 190 190 190 190 190
L3-24
Motor Accel
Time for
Inertia Cal
s 0.145 0.145 0.145 0.154 0.154 0.168 0.168 0.175
L8-02
Overheat
Alarm Level
°C 124 124 110 110 110 110 110 110
L8-09
Output Ground
Fault
Detection
- 1 1 1 1 1 1 1 1
L8-38
Carrier
Frequency
Reduction
- 2 2 2 2 2 2 2 2
n1-01
Hunting
Prevention
Selection
- 1 1 1 1 1 1 1 1
n1-03
Hunting
Prevention
Time Constant
ms 10 10 10 10 10 10 10 10
n5-02
Motor Inertia
Acceleration
Time
s 0.145 0.145 0.145 0.154 0.154 0.168 0.168 0.175
*1 Parameters within parentheses are for motor 2.