EasyManua.ls Logo

YASKAWA GA800

YASKAWA GA800
644 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.8 H: Terminal Functions
358 YASKAWA TOEPYAIGA8002B GA800 Drive Programming
Setting Value Function Reference
45 Add Offset Frequency 2 (d7-02)
374
46 Add Offset Frequency 3 (d7-03)
374
47 Node Setup (CANopen)
374
60 DC Injection Braking Command
374
61 Speed Search from Fmax
375
62 Speed Search from Fref
375
63 Field Weakening
375
65
*1
KEB Ride-Thru 1 Activate (N.C.)
375
66
*1
KEB Ride-Thru 1 Activate (N.O.)
376
67 Communications Test Mode
376
68 High Slip Braking (HSB) Activate
376
6A Drive Enable
376
71 Torque Control
376
72 Zero Servo
377
Setting Value Function Reference
75 Up 2 Command
377
76 Down 2 Command
378
77 ASR Gain (C5-03) Select
379
78 Analog TorqueRef Polarity Invert
379
7A
*1
KEB Ride-Thru 2 Activate (N.C.)
379
7B
*1
KEB Ride-Thru 2 Activate (N.O.)
379
7C
*1
Short Circuit Braking (N.O.)
380
7D
*1
Short Circuit Braking (N.C.)
380
7E Reverse Rotation Identifier
380
90 to 97
*1
DWEZ Digital Inputs 1 to 8
380
9F DWEZ Disable
380
101 to 19F Inverse Inputs of 1 to 9F
Sets the function of the selected MFDI to operate
inversely. To select the function for inverse input, enter
two digits 01 to 9F for the xx in 1xx.
381
*1 Inverse input is not available.
H1-01: Terminal S1 Function Selection
No.
(Hex.)
Name Description
Default
(Range)
H1-01
(0438)
Terminal S1 Function
Selection
Sets the function for MFDI terminal S1.
40
(1 - 1FF)
Note:
The default setting is F when the drive is initialized for 3-Wire Initialization [A1-03 = 3330].
H1-02: Terminal S2 Function Selection
No.
(Hex.)
Name Description
Default
(Range)
H1-02
(0439)
Terminal S2 Function
Selection
Sets the function for MFDI terminal S2.
41
(1 - 1FF)
Note:
The default setting is F when the drive is initialized for 3-Wire Initialization [A1-03 = 3330].
H1-03: Terminal S3 Function Selection
No.
(Hex.)
Name Description
Default
(Range)
H1-03
(0400)
Terminal S3 Function
Selection
Sets the function for MFDI terminal S3.
24
(0 - 1FF)
H1-04: Terminal S4 Function Selection
No.
(Hex.)
Name Description
Default
(Range)
H1-04
(0401)
Terminal S4 Function
Selection
Sets the function for MFDI terminal S4.
14
(0 - 1FF)
H1-05: Terminal S5 Function Selection
No.
(Hex.)
Name Description
Default
(Range)
H1-05
(0402)
Terminal S5 Function
Selection
Sets the function for MFDI terminal S5.
3
(0 - 1FF)
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV

Table of Contents

Other manuals for YASKAWA GA800

Related product manuals