5.9 n: Special Adjustments
322 YASKAWA ELECTRIC SIEP C710636 02B YASKAWA U1000 Technical Manual
n1-10: Suppression Frequency
There is normally no need to change this parameter from the default value.
Note: This parameter is available in the drive software versions S1017 and later.
n1-11: Suppression Auxiliary Frequency
There is normally no need to change this parameter from the default value.
Note: This parameter is available in the drive software versions S1017 and later.
n1-12: Vibration Suppression Time Constant
There is normally no need to change this parameter from the default value.
Note: This parameter is available in the drive software versions S1017 and later.
n2: Speed Feedback Detection Control (AFR) Tuning
These parameters are used to achieve speed stability when a load is suddenly applied or removed.
Note: Before making changes to the AFR parameters, make sure all motor parameters are set properly or perform Auto-Tuning.
n2-01: Speed Feedback Detection Control (AFR) Gain
Sets the internal speed feedback detection control gain in the AFR.
Normally there is no need to adjust n2-01 from the default setting. Make adjustments in the following cases:
If hunting occurs, increase the setting value in steps of 0.05 while checking the response.
If response is low, decrease the setting value in steps of 0.05 while checking the response.
n2-02: Speed Feedback Detection Control (AFR) Time Constant 1
Parameter n2-02 sets the time constant normally used by AFR.
These parameters rarely need to be changed. Adjust settings only under the following conditions:
If hunting occurs, increase n2-02. If response is low, decrease it.
If setting n2-02 to a higher value, also increase C4-02 (Torque Compensation Primary Delay Time) proportionally.
n3: Overexcitation Braking
Overexcitation Deceleration (Induction Motors)
Overexcitation Deceleration increases the flux during deceleration and allows shorter deceleration time settings. Enabled
by setting L3-04 to 4. See L3-04: Stall Prevention Selection during Deceleration on page 305.
Notes on Overexcitation Deceleration
During Overexcitation Deceleration 2, Hunting Prevention in V/f Control and torque limits in Open Loop Vector
Control are disabled.
No. Name Setting Range Default
n1-10 Suppression Frequency 5.0 to 100.0 Hz 10.0 Hz
No. Name Setting Range Default
n1-11 Suppression Auxionary Frequency 10.0 to 50.0 Hz 20.0 Hz
No. Name Setting Range Default
n1-12 Vibration Suppression Time Constant 0 to 1000 ms 0 ms
No. Name Setting Range Default
n2-01 Speed Feedback Detection Control (AFR) Gain 0.00 to 10.00 1.00
No. Name Setting Range Default
n2-02
Speed Feedback Detection Control (AFR) Time Constant 1
0 to 2000 ms 50 ms