<7>
A+
A
B
Z
B+
Z+
AO
IG
BO
IG
ZO
IG
FE
IP
IG
TB1
SD
TB2
B track monitor
A track monitor
M
U/T
1
V/T
2
W/T
U
V
W
3
Ground
PG
+
−
+
+
+
−
+
−
S
1
S
2
S
3
S
4
S
5
S
6
S
7
MP
DM
DM
RP
A
1
A
2
A
3
0
V
AC
R
R
S
S
IG
H
1
H
2
HC
CIMR-U40720 to 40930
p1
n1
2
kΩ
S
8
SC
FM
AM
0
V
0
V
AC
FM
AM
AC
E (G)
S
1
S
2
<14>
<10>
<15>
<13>
<13>
<11>
<12>
<10>
<8>
<6>
<3>
VI
+24
V
+
V
MA
M
1
M
2
P
1
P
2
MB
MC
PC
CN5-C
CN5-B
CN5-A
Forward Run / Stop
Reverse Run / Stop
External fault
Fault reset
Multi-speed step 1
Multi-speed step 2
External Baseblock
Jog speed
Multi-function
digital inputs
(default setting)
Sink / Source mode
selection jumper S3
(default: Sink)
Option board
connectors
Pulse Train Input (max 32 kHz)
Shield ground terminal
Multi-function
analog/ pulse
train inputs
Power supply +10.5 Vdc, max. 20 mA
Analog Input 1
(Frequency Reference Bias)
0 to +10 Vdc (20 k
Ω
)
Analog Input 2
(Frequency Reference Bias)
0 to +10 Vdc (20 k
Ω
)
4 to 20 mA / 0 to 20 mA (250
Ω
)
Analog Input 3
(Aux. frequency reference)
0 to +10 Vdc (20 k
Ω
)
−
V
Power supply, -10.5 Vdc, max. 20 mA
Safety
Switch
MEMOBUS/Modbus
comm. RS-422/RS-485
max. 115.2 kbps
Safe Disable inputs
Wire
jumper
Open
Safety relay /
controller
Termination resistor
(120
Ω
, 1/2 W)
DIP
Switch S2
DIP Switch S1
Fault relay output
<9>
250 Vac, max. 1 A
30 Vdc, max 1 A
(min. 5 Vdc, 10 mA)
Multi-function relay output
(During Run)
250 Vac, max. 1 A
30 Vdc, max 1 A
(min. 5 Vdc, 10 mA)
Multi-function photo coupler output 1
(Zero Speed)
48 Vdc, max 50 mA
Multi-function photo coupler output 2
(Speed Agree 1)
48 Vdc, max 50 mA
Multi-function pulse train output
(Output frequency)
0 to 32 kHz (2.2 k
Ω
)
Multi-function analog output 1
(Output frequency)
-10 to +10 Vdc (2mA)
Multi-function analog output 2
(Output current)
-10 to +10 Vdc (2mA)
EDM
(Safety Electronic Device Monitor)
Main Circuit
Control Circuit
shielded line
twisted-pair shielded line
main circuit terminal
control circuit terminal
PGB3
MC
2MCCB
MB
ON
OFF
THRX
SA
1
2
TRX
MC
MA
TRX
Fault relay
contact
Braking resistor unit
Thermal relay trip contact
MC
MC
SA
SA
THRX
Terminals p1, n1 are for connection
options. Never connect power supply
lines to these terminals.
0 V
24 V 24
0
FE
24 V Control Power Supply
Unit Terminals
<16>
ELCB (MCCB)
R
T
S
MC
Three-phase
power supply
380 to 500 V
50/60 Hz
Wiring sequence should shut off
power to the drive when a fault
output is triggered.
If running from a 400 V power
supply, a step-down transformer
is needed to
reduce the voltage to 200 V.
<1>
<2>
Cooling fan
M
FU
FV
FW
<5>
X
Y
Z
R/L1
S/L2
T/L3
X1
Y1
Z1
X1
Y1
Z1
p2
n2
p2
n2
r1/ℓ11
t1/ℓ31
X
Y
Z
r1/ℓ11
t1/ℓ31
2MCCB
Harmonic
lter module
1/ℓ21
1/ℓ21
<4>
CN500
㸦20pin㸧
CN500