3.3 Main Circuit Connection Diagram
YASKAWA ELECTRIC
SIEP C710636 02B YASKAWA U1000 Technical Manual 79
3.3 Main Circuit Connection Diagram
Refer to the Figure 3.5 when wiring the main circuit of the drive.
Figure 3.5
Figure 3.5 Drive main circuit configurations
Figure 3.6
CIMR-U20028 to 20248, 40011 to 40590
<1> A Momentary Power Loss Recovery Unit can be connected as an option. Do not connect an AC power supply to these terminals.
CIMR-U40720 to 40930, Harmonic Filter Module
<1> A Momentary Power Loss Recovery Unit can be connected as an option. Do not connect an AC power supply to these terminals.
Input filter
R/L1
S/L2
T/L3
U/T1
V/T2
W/T3
Control
board
Bidirectional IGBT
Control power supply
p1
n1
<1>
<1>
Control
power
supply
Harmonic filter module
Control
board
p1 <1>
r1/
11
CIMR-U40720 to 40930
n1
<1>
U/T1
W/T3
V/T2
Bidirectional
IGBT
R/L1
X1
Y1
Z1
p2
n2
X
Y
Z
X1
Y1
Z1
p2
n2
X
Y
Z
T/L3
S/L2
Input
filter
Input
filter
FAN
power
supply
1/ 21
t1/ 31
r1/
11
1/ 21
t1/ 31
SIEP_C710636_02B_1_0.book 79 ページ 2015年11月25日 水曜日 午後4時56分