D.3 UL Standards
YASKAWA ELECTRIC
SIEP C710636 02B YASKAWA U1000 Technical Manual 599
Table D.7 Harmonic Filter Module Wire Gauge and Torque Specifications for CIMR-UB40720 to 40930
Model
<1> When wiring the ground wire, additional measures must be taken in accordance with IEC/EN 61800-5-1.
Terminal
Recomm. Gauge
AWG, kcmil
Applicable Gauge
AWG, kcmil
Screw
Size
Tightening Torque
Nm (lb.in.)
EUJ71186.
<1>
R/L1, S/L2, T/L3 300 × 4P 250 to 300 × 4P M12
31.4 to 39.2
(278 to 347)
X, Y, Z 300 × 4P 250 to 300 × 4P M12
31.4 to 39.2
(278 to 347)
X1, Y1, Z1 1/0 1/0 to 2/0 M8
5.4 to 6.0
(47.8 to 53.0)
3/0 3/0 to 300 M12
31.4 to 39.2
(278 to 347)
r1, 1, t1
14 14 to 12 M4
1.2 to 2.0
(10.4 to 17.4)
p2, n2 14 14 to 12 M4
1.2 to 2.0
(10.4 to 17.4)
EUJ71187.
<1>
R/L1, S/L2, T/L3 4/0 × 8P
300 × 4P
2/0 to 300 × 8P
M12
31.4 to 39.2
(278 to 347)
X, Y, Z 4/0 × 8P
300 × 4P
2/0 to 300 × 8P
M12
31.4 to 39.2
(278 to 347)
X1, Y1, Z1 1/0 1/0 to 2/0 M8
5.4 to 6.0
(47.8 to 53.0)
4/0 4/0 to 300 M12
31.4 to 39.2
(278 to 347)
r1, 1, t1
14 14 to 12 M4
1.2 to 2.0
(10.4 to 17.4)
p2, n2 14 14 to 12 M4
1.2 to 2.0
(10.4 to 17.4)
EUJ71188.
<1>
R/L1, S/L2, T/L3 4/0 × 8P 4/0 to 300 × 8P M12
31.4 to 39.2
(278 to 347)
X, Y, Z 4/0 × 8P 4/0 to 300 × 8P M12
31.4 to 39.2
(278 to 347)
X1, Y1, Z1 1/0 1/0 to 2/0 M8
5.4 to 6.0
(47.8 to 53.0)
4/0 4/0 to 300 M12
31.4 to 39.2
(278 to 347)
r1, 1, t1
14 14 to 12 M4
1.2 to 2.0
(10.4 to 17.4)
p2, n2 14 14 to 12 M4
1.2 to 2.0
(10.4 to 17.4)
SIEP_C710636_02B_1_0.book 599 ページ 2015年11月25日 水曜日 午後4時56分