12 PERIODIC MAINTENANCE
Check the wear and the condition of the contactors’ moving and fixed contacts.
Electrical contacts should be checked every 3 months.
Check the Foot pedal or seat microswitch. Using a suitable test meter, confirm
that there is no electrical resistance between the contacts by measuring the
voltage drop between the terminals. Switches should operate with a clear click
sound.
Microswitches should be checked every 3 months.
Check the Battery cables, cables connected to the inverter, and cables
connected to the motor. Ensure that the insulation is sound and that the
connections are tight.
Cables should be checked every 3 months.
Check the mechanical functionality of the pedals or tiller. Control that the return
springs are ok and that the potentiometers excursion matches their full or
programmed level.
Check every 3 months.
Check the mechanical functionality of the Contactor(s). Moving contacts should
be free to move without restriction.
Check every 3 months.
Checks should be carried out by qualified personnel and any replacement parts
used should be original. Beware of NON ORIGINAL PARTS.
The installation of this electronic controller should be made according to the
diagrams included in this Manual. Any variations or special modifications should
be evaluated with a Zapi Agent. The supplier is not responsible for any problem
that arises from connections that differ from information included in this Manual.
During periodic checks, if a technician finds any situation that could cause
damage or compromise safety, the matter should be brought to the attention of a
Zapi Agent immediately. The Agent will then take the decision regarding the
operational safety of the machine.
Remember that Battery Powered Machines feel no pain.
NEVER USE A VEHICLE WITH A FAULTY ELECTRONIC CONTROLLER.
IMPORTANT NOTE ABOUT WASTE MANAGEMENT:
This controller has both mechanical parts and high-density electronic parts
(printed circuit boards and integrated circuits). If not properly handled
during waste processing, this material may become a relevant source of
pollution. The disposal and recycling of this controller has to follow the
local laws for these kinds of waste materials.
Zapi commits itself to update its technology in order to reduce the
presence of polluting substances in its products.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zapi DUALACE2 NEW GENERATION and is the answer not in the manual?

Zapi DUALACE2 NEW GENERATION Specifications

General IconGeneral
BrandZapi
ModelDUALACE2 NEW GENERATION
CategoryController
LanguageEnglish

Related product manuals