ADJUSTMENTS
Parameter
Allowable range
Description
A.SENS.MIN CE
(Only for BLE version
with sin/cos sensor)
(A)
Volt
This parameter records the minimum offset voltage at the
cosine analog input during the auto-teaching procedure.
It can be compared with the A.SENS.OFFSET CR entry
value.
TOOTHS OFF.ANGLE
(Only for BLE version
with zero-index
encoder)
(A)
This parameter records the angle offset of index signal
input during the auto-teaching procedure.
OFFSET ANGLE
(Only for BLE version
with sin/cos sensor or
sixstep)
(A)
0° - 180°
(steps of 0.1°)
This parameter gives the possibility to manually adjust the
offset angle present between the absolute position sensor
and the PMSM rotor orientation. The unit is degrees and
the max value is 180°.
HYST. ANGLE
(Only for BLE version
with sixstep)
(A)
This parameter records the hysteresis angle present
between the absolute position sensor and the PMSM rotor
orientation during the auto-teaching procedure.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zapi DUALACE2 NEW GENERATION and is the answer not in the manual?

Zapi DUALACE2 NEW GENERATION Specifications

General IconGeneral
BrandZapi
ModelDUALACE2 NEW GENERATION
CategoryController
LanguageEnglish

Related product manuals