Page 92/169 AFNZPxxx DUALACE2 NEW GENERATION User Manual
SPECIAL ADJUSTMENTS
Parameter
Allowable range
Description
SAFETY LEVEL
(A)
0 ÷ 3
This parameter defines the safety level of the controller, i.e.
the functionality of the supervisor microcontroller.
0 = Supervisor µC does not check any signal.
1 = Supervisor µC checks the inputs and the outputs.
2 = Supervisor µC checks the inputs and the motor set-
point.
3 = Supervisor µC checks the inputs, the outputs and
the motor set-point.
RS232 CONSOLLE
(A)
OFF ÷ ON
This parameter enables or disables the console to change
settings.
NOTE: only Zapi technicians can change this value.
NODE ID OFST
(CO)
0 ÷ 126
(by steps of 1)
This parameter defines the offset of the CAN frame IDs.
ID CANOPEN OFST
(CO)
0 ÷ 56
(by steps of 8)
This parameter defines the offset of the Open CAN frame
IDs.
2ND SDO ID OFST
(A)
0 ÷ 126
(by steps of 2)
This parameter defines if another SDO communication
channel has to be added. Specify an ID offset different from
0 in order to enable the channel.
VDC START UP LIM
(A)
by 1% steps)
This parameter defines the battery voltage (as percentage
of the nominal voltage) above which delivered power is
reduced in order to avoid an overvoltage condition during
braking.
VDC UP LIMIT
(A)
0% ÷ 255%
(by 1% steps)
This parameter defines the battery voltage (as percentage
of the nominal voltage) above which the inverter stops in
order to avoid a triggering of overvoltage condition.
VDC START DW LIM
(A)
0% ÷ 255%
(by 1% steps)
This parameter defines the battery voltage (as percentage
of nominal voltage) below which delivered power is reduced
in order to avoid an undervoltage condition (typically during
accelerations with low battery).
VDC DW LIMIT
(A)
0% ÷ 255%
(by 1% steps)
This parameter defines the battery voltage (as percentage
of nominal voltage) below which the inverter stops in order
to avoid an uncontrolled shutdown due to an undervoltage
condition.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zapi DUALACE2 NEW GENERATION and is the answer not in the manual?

Zapi DUALACE2 NEW GENERATION Specifications

General IconGeneral
BrandZapi
ModelDUALACE2 NEW GENERATION
CategoryController
LanguageEnglish

Related product manuals