Radio Communications 4 - 37
Page Options
To select a page option, select one of the bar codes below.
Page Mode
Parameter # 1364 (SSI # F8h 05h 54h)
•
Page State - In this mode, the cradle sends a page state request to each scanner. It remains in Page State
indication until every scanner sends an acknowledgment.
The scanner enters Page State when the LED indicator is blinking blue and the vibrator and beeper is
activated. When the trigger is pressed, or the scanner is inserted into the cradle, or the requested timeout
(default is 30 sec) is reached, the scanner sends the acknowledgment to the cradle and returns to its normal
state.
•
Page Simple - In this mode, the cradle sends a page indication request to each scanner, and returns to idle
state. Each scanner issues a single Page State indication.
Page State Timeout
Parameter # 1365 (SSI # F8h 05h 55h)
Page timeout is programmable in 1 second increments from 1 to 99 seconds. The default timeout is 30 seconds.
To set a page timeout:
1. Scan the Page Timeout bar code below.
2. Scan two numeric bar codes from Numeric Bar Codes on page G-1 that correspond to the desired timeout
duration. Enter a leading zero for single digit numbers (for example, for a 5 second page timeout, scan the 0
bar code and then the 5 bar code). To correct an error or change the selection, scan Cancel on page H-1.
The Page State Timeout default is 30 seconds.
Page State
*Page Simple
NOTE Page State Timeout only applies to Page State Mode.
Page Timeout