Configuration
Configuration and Calibration Sequence
Z4Mplus and Z6Mplus User Guide 77
Power-Up and Head Close Parameters
MEDIA POWER UP Press SELECT to make change.
Media Power Up: Press PLUS (+) or MINUS () to display
other choices.
Default: Calibration
Selections: Calibration, length, no motion, and feed
Press SELECT to accept the change.
This parameter establishes the action of the media when the
printer is turned on.
Calibration: Recalibrates the media and ribbon sensors.
Feed: Feeds the label to the first web.
Length: Determines the length of the label.
No Motion: Media does not move.
HEAD CLOSE Press SELECT to make change.
Head Close: Press PLUS (+) or MINUS () to display other
choices.
Default: Calibration
Selections: Calibration, length, no motion, and feed
Press SELECT to accept the change.
Determines the action of the media after the printhead has
been opened and then closed.
Calibration: Recalibrates the media and ribbon sensors.
Feed: Feeds the label to the first web.
Length: Determines the length of the label.
No Motion: Media does not move.