MAINTENANCE
Page 49
10.0 MAINTENANCE
10.1 CONTROL PROCESSOR
The Processor requires the following annual checks:
• Check all terminal connections for signs of corrosion or loose
connections.
• Check mechanical connections within the Processor.
• Check mechanical connetions at the transmission.
• Check mechanical movement of the transmission selector
lever. Ensure that the cable does not jam while positioning
the selector lever.
• Cycle the Processor and if lead screws are noisy, apply a light
coating of silicone grease to the stainless steel lead screw.
10.2
CONTROL HEAD
Verify once a year that Control Head terminals are secure and free of
corrosion. Apply a light coating of Teflon grease, or corrosion block,
to the contacts.