TROUBLESHOOTING
Page 6
again blows, the circuit board needs repair or replaced with a
Circuit Board Kit.
1.9
SYMPTOM - THE ENGINE STARTS TO TURN OVER WHILE STARTING
AND THEN STOPS. A SLOW REPETITIVE AUDIBLE TONE FROM ALL
CONTROL HEAD STATIONS.
Cause:
A)The voltage to the Processor has dropped too low, due to the
starters current requirements.
B) Battery charge is low.
Remedy:
A)Supply power to the Processor from a battery other then the
starting battery.
B) Recharge or replace the battery.
1.10
THE ENGINE WILL NOT START.
Cause:
A)ClearCommand does not have power turned ON.
B) ClearCommand does not have a Station in command.
C) The Control Head levers at the Station-in-Command are not at
the Idle position.
D)Low battery voltage.
E) Faulty start interlock circuit in the Processor.
F) Faulty wire or component in the starting system.
G)System is in Set-up Mode (Jumper 2 Closed )
Remedy:
A)Turn power ON to the ClearCommand System.
B) Take command at a Station.
C) Place the Station-in-Command Control Head levers into the
Idle position.
D)Check the battery voltage. If the voltage is low, charge or
replace the battery.