200 Parameters
30.13 Minimum frequency Defines together with 30.14 Maximum frequency allowed
frequency range. See the figure below.
A positive (or zero) minimum frequency value defines two
ranges, one positive and one negative.
A negative minimum frequency value defines one range.
WARNING! The absolute value of 30.13 Minimum
frequency must not be higher than 30.14
Maximum frequency.
WARNING! in frequency control mode only.
-50.00 Hz
-500.00…500.00 Hz Minimum frequency. See par.
46.02
30.14 Maximum frequency Defines together with 30.13 Minimum frequency allowed
frequency range. See 30.13 Minimum frequency.
Note: This parameter does not affect the speed
acceleration and deceleration ramp times. See parameter
46.02 Frequency scaling.
WARNING! This absolute value of 30.14
Maximum frequency must not be lower than 30.13
Minimum frequency.
WARNING! In frequency control mode only.
50.00 Hz
-500.00…500.00 Hz Maximum frequency. See par.
46.02
No. Name/Value Description Default
FbEq 16
Frequency
Frequency range allowed
Frequency range allowed
Frequency range allowed
Time
Frequency
Time
0
0
30.13 value is < 0
30.14
30.13
30.13 value is >
0
30.14
30.13
-30.13
-30.14
ACS180 FW.book Page 200 Tuesday, March 9, 2021 2:25 PM