ACS2000 User manual 2UEA001270 Rev. F 9-23 (24)
Chapter 9 - CDP control panel
9.4.3 Entering a setpoint
A setpoint can be changed at any time if the CDP control panel has been
set to local.
1 To enter a control
panel mode displaying
the status row, press a
mode key.
2 To enter the setpoint
setting function, press
the REF key.
3 To change the
setpoint, press either
the corresponding fast
or slow navigation
key.
4 To exit the setpoint
setting mode, press
any of the mode keys.
1 L ->
600.0 rpm
StateINU
MOTOR SP
POWER
ReadyRun
600.00 rpm
75.0 kW
0
1 L ->
[600.0 rpm]
StateINU
MOTOR SP
POWER
ReadyRun
600.00 rpm
75.0 kW
0
1 L ->
[550.0 rpm]
StateINU
MOTOR SP
POWER
ReadyRun
600.00 rpm
75.0 kW
0
1 L ->
550.0 rpm
StateINU
MOTOR SP
POWER
ReadyRun
550.00 rpm
75.0 kW
0