Parameters 285
58.111 Data I/O 11 Parameter selector for Modbus register address 400011.
For the selections, see parameter 58.101 Data I/O 1.
None
TPDO6 word 3 Selects a parameter that is mapped to TPDO6 word 3. For
selections, see parameter 58.101 TPDO1 word 1.
None
58.112 Data I/O 12 Parameter selector for Modbus register address 400012.
For the selections, see parameter 58.101 Data I/O 1.
None
TPDO6 word 4 Selects a parameter that is mapped to TPDO6 word 4. For
selections, see parameter 58.101 TPDO1 word 1.
None
58.113 Data I/O 13 Parameter selector for Modbus register address 400013.
For the selections, see parameter 58.101 Data I/O 1.
None
RPDO6 word 1 Selects a parameter that is mapped to RPDO6 word 1.
For selections, see parameter 58.101 TPDO1 word 1.
None
58.114 Data I/O 14 Parameter selector for Modbus register address 400014.
For the selections, see parameter 58.101 Data I/O 1.
None
RPDO6 word 2 Selects a parameter that is mapped to RPDO6 word 2.
For selections, see parameter 58.101 TPDO1 word 1.
None
58.115 RPDO6 word 3 Selects a parameter that is mapped to RPDO6 word 3.
For selections, see parameter 58.101 TPDO1 word 1.
Note: If parameter 58.01 = [1] Modbus RTU, this
parameter is hidden.
None
58.116 RPDO6 word 4 Selects a parameter that is mapped to RPDO6 word 4.
For selections, see parameter 58.101 TPDO1 word 1.
Note: If parameter 58.01 = [1] Modbus RTU, this
parameter is hidden.
None
58.117 TPDO21 word 1 Selects a parameter that is mapped to TPDO21 word 1.
For selections, see parameter 58.101 TPDO1 word 1.
Note: If parameter 58.01 = [1] Modbus RTU, this
parameter is hidden.
None
58.118 TPDO21 word 2 Selects a parameter that is mapped to TPDO21 word 2.
For selections, see parameter 58.101 TPDO1 word 1.
Note: If parameter 58.01 = [1] Modbus RTU, this
parameter is hidden.
None
58.119 TPDO21 word 3 Selects a parameter that is mapped to TPDO21 word 3.
For selections, see parameter 58.101 TPDO1 word 1.
Note: If parameter 58.01 = [1] Modbus RTU, this
parameter is hidden.
None
58.120 TPDO21 word 4 Selects a parameter that is mapped to TPDO21 word 4.
For selections, see parameter 58.101 TPDO1 word 1.
Note: If parameter 58.01 = [1] Modbus RTU, this
parameter is hidden.
None
58.121 RPDO21 word 1 Selects a parameter that is mapped to RPDO21 word 1.
For selections, see parameter 58.101 TPDO1 word 1.
Note: If parameter 58.01 = [1] Modbus RTU, this
parameter is hidden.
None