Actual signals and parameters
104
62.08 REV REG OUT This is set to a default value by the program, depending on the macro
selected. If the PI regulator is adjusting the speed in the wrong
direction it can be reversed here. See 60.05 WINDING MODE for
expected machine orientation
NO – WINDER Regulator output is not reversed. Default for winder macro. 1
YES – UNWIND Regulator output is reversed. Default for unwind macro. 2
DI2 Digital input DI2 = 1 reverses the regulator output. 3
DI3 See selection DI2. 4
DI4 See selection DI2. 5
DI5 See selection DI2. 6
DI6 See selection DI2. 7
DI7 See selection DI2. 8
DI8 See selection DI2. 9
DI9 See selection DI2. 10
DI10 See selection DI2. 11
DI11 See selection DI2. 12
DI12 See selection DI2. 13
FIELDBUS See selection DI2. Instead of a digital input, the command comes from
06.03 DATASET 1 WORD 3 bit 15. See chapter Fieldbus control.
14
62.09 DANCER CTL ENABLE Set to “ENABLE” if this is a single position machine and there are no
requirements to ever RUN without dancer control.
Set to a DI or FBA option if this is a turret or if there are some
instances where the dancer regulation should be ignored in RUN
mode.
NOT SEL Not enabled. The drive is in “pure” speed mode. 1
YES Enabled. When the drive is in run, the dancer regulation trim is active. 2
DI2 Digital input DI2 = 1 enables the regulation trim. Otherwise it is in
“pure” speed mode.
3
DI3 See selection DI2. 4
DI4 See selection DI2. 5
DI5 See selection DI2. 6
DI6 See selection DI2. 7
DI7 See selection DI2. 8
DI8 See selection DI2. 9
DI9 See selection DI2. 10
DI10 See selection DI2. 11
DI11 See selection DI2. 12
DI12 See selection DI2. 13
FIELDBUS See selection DI2. Instead of a digital input, the command comes from
06.03 DATASET 1 WORD 3 bit 00. See chapter Fieldbus control.
14
PARAM 62.32 Source selected by 62.32 DAN CTRL ENBL PTR. 15
No. Name/Value Description FbEq