EasyManua.ls Logo

ABB ACS800 Series - Torque Mem Ctrl

ABB ACS800 Series
214 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Actual signals and parameters
122
AI6 Uses a sensor on analog input AI6 (voltage or current). 5
65.22 DIA HOLD PTR This parameter defines the source to hold the diameter calculation. An
input of binary 1 will hold the calculation.
-255.255.31…+255.255.31
/ C.-32768 …C.32767
Parameter index or a constant value. See 10.05 EXT1 STRT PTR for
information on the difference.
-
66 TORQUE MEM CTRL
Torque memory control and setup. Typically used on turret winders.
66.01 TORQUE MEM SAMPLE Selects the activation signal source for torque sampling.
NOT SEL Torque memory is not used. 1
DI2 Digital input DI2 = 1 memorizes the actual motor torque. 2
DI3 See selection DI2. 3
DI4 See selection DI2. 4
DI5 See selection DI2. 5
DI6 See selection DI2. 6
DI7 See selection DI2. 7
DI8 See selection DI2. 8
DI9 See selection DI2. 9
DI10 See selection DI2. 10
DI11 See selection DI2. 11
DI12 See selection DI2. 12
FIELDBUS See selection DI2. Instead of a digital input, the command comes from
06.03 DATASET 1 WORD 3 bit 11. See chapter Fieldbus control.
13
No. Name/Value Description FbEq
Tension/Dancer MUST be enabled during cycle.
Start of
index
Finishing roll
is isolated
Sample torque
for torque mem
Torque mem
enable
cut
Time Delay
66.03
Torque Boost
after time delay
Notes:
Mechanical operations:
ACS800 controlled operations
Torque sample OFF
Torque mem OFF
Tension OFF
Stop winder
Remove finished roll
Reset diameter
Time
Knife

Table of Contents