Program features
29
Programmable digital inputs 
The drive has six programmable digital inputs as a standard. Six extra inputs are 
available if the optional Digital I/O Extension Modules are used.
Update cycles in the Control Program
Settings
Diagnostics
Input Cycle
DI / standard 50 ms
DI / extension  50 ms
Parameter Additional Information
Group 10 START/STOP/DIR Start, stop, direction source
Group 11 REFERENCE SELECT Reference selection, reference source
Group 12 CONSTANT SPEEDS Constant speed selection
Group 16 SYS CTRL INPUTS External run enable, fault reset, user macro change
Group 61 CORE SPEED MATCH Digital potentiometer for reference
Group 62 DANCER CONTROLS Regulator control
Group 63 TENSION CONTROLS Regulator control
Group 65 DIA CALC CONTROL Diameter reset
Group 66 TORQUE MEM CTRL Torque memory control
98.03…98.04 Activation of the optional Digital I/O Extension Modules
Actual Value Additional Information
01.17 Standard digital inputs
01.40 Optional digital inputs
Warning
IO CONF Improper use of optional I/O