Loading...
Actual signals and parameters
132
98 OPTION MODULES
Activation of the optional I/O extension modules and fieldbus adapter.
For more information on option modules, see the module manuals.
These parameter settings will remain the same even if the macro is
changed.
98.01 ENCODER MODULE Activates the communication to the optional pulse encoder module.
NTAC Communication active. Module type: NTAC module. Connection
interface: Fibre optic DDCS link.
Note: Module node number must be set to 16. For directions, see
Installation and Start-up Guide for NTAC-0x/NDIO-0x/NAIO-0x
Modules (Code: 3AFY58919730 [English]).
0
NO Inactive. 1
RTAC-SLOT1 Communication active. Module type: RTAC. Connection interface:
Option slot 1 of the drive.
2
RTAC-SLOT2 Communication active. Module type: RTAC. Connection interface:
Option slot 2 of the drive.
3
RTAC-DDCS Communication active. Module type: RTAC. Connection interface:
Optional I/O module adapter (AIMA) that communicates with the drive
through a fibre optic DDCS link.
Note: Module node number must be set to 16. For directions, see
Users Manual for RDIO Module (Code: 3AFE64485733 [English]).
4
RRIA-SLOT1 Communication active. Module type: RRIA. Connection interface:
option slot 1 of the drive.
5
RRIA-SLOT2 Communication active. Module type: RRIA. Connection interface:
option slot 2 of the drive.
6
RRIA-DDCS Communication active. Module type: RRIA. Connection interface:
Optional I/O module adapter (AIMA) that communicates with the drive
through a fibre optic DDCS link.
Note: Module node number must be set at 16. For directions, see
RRIA-01 Resolver Interface Module User’s Manual [3AFE68570760
(English)].
7
RTAC03-SLOT1 Communication active. Module type: RTAC. Connection interface:
option slot 1 of the drive.
8
RTAC03-SLOT2 Communication active. Module type: RTAC. Connection interface:
option slot 2 of the drive.
9
RTAC03-DDCS Communication active. Module type: RTAC. Connection interface:
Optional I/O module adapter (AIMA) that communicates with the drive
through a fibre optic DDCS link.
Note: Module node number must be set at 16. For directions, see
RRIA-01 Resolver Interface Module User’s Manual [3AFE68570760
(English)].
10
98.02 FIELDBUS MODULE Activates the external serial communication and selects the interface.
See chapter Fieldbus control.
NO No communication. 1
FIELDBUS The drive communicates via a fieldbus adapter module in option slot 1
of the drive, or via CH0 on the RDCO board. See also group 51
FIELDBUS DATA.
2
ADVANT The drive communicates with an ABB Advant OCS system via CH0 on
the RDCO board (optional). See also group 70 DDCS CONTROL.
3
No. Name/Value Description FbEq