Control panel
13
Actual signal display mode
In the Actual Signal Display Mode, the user can:
show three actual signals on the display at a time
select the actual signals to display
view the fault history
reset the fault history.
The panel enters the Actual Signal Display Mode when the user presses the ACT
key, or does not press any key within one minute.
How to select actual signals to the display
Step Action Press Key Display
1. To enter the Actual Signal Display
Mode.
1 L -> 1242.0 rpm I
F
REQ 45.00 Hz
CURRENT 80.00 A
POWER 75.00 %
2. To select a row (a blinking cursor
indicates the selected row).
1 L -> 1242.0 rpm I
FREQ 45.00 Hz
C
URRENT 80.00 A
POWER 75.00 %
3. To enter the actual signal selection
function.
1 L -> 1242.0 rpm I
1 ACTUAL SIGNALS
04 CURRENT
80.00 A
4. To select an actual signal.
To change the actual signal group.
1 L -> 1242.0 rpm I
1 ACTUAL SIGNALS
05 TORQUE 70.00 %
5.a To accept the selection and return to the
Actual Signal Display Mode.
1 L -> 1242.0 rpm I
FREQ 45.00 Hz
T
ORQUE 70.00 %
POWER 75.00 %
5.b To cancel the selection and keep the
original selection.
The selected keypad mode is entered.
1 L -> 1242.0 rpm I
FREQ 45.00 Hz
C
URRENT 80.00 A
POWER 75.00 %
ACT
ENTER
ENTER
ACT
FUNC DRIVE
PAR