Control panel
13
Actual signal display mode
In the Actual Signal Display Mode, the user can:
• show three actual signals on the display at a time
• select the actual signals to display
• view the fault history
• reset the fault history.
The panel enters the Actual Signal Display Mode when the user presses the ACT 
key, or does not press any key within one minute.
How to select actual signals to the display
Step Action Press Key Display
1. To enter the Actual Signal Display 
Mode.
 1 L -> 1242.0 rpm I
F
REQ       45.00 Hz
CURRENT    80.00 A
POWER      75.00 %
2. To select a row (a blinking cursor 
indicates the selected row). 
 1 L -> 1242.0 rpm I
FREQ       45.00 Hz
C
URRENT    80.00 A
POWER      75.00 %
3. To enter the actual signal selection 
function.
 1 L -> 1242.0 rpm I
1 ACTUAL SIGNALS
04 CURRENT
  80.00 A
4. To select an actual signal.
To change the actual signal group.
 1 L -> 1242.0 rpm I
1 ACTUAL SIGNALS
05 TORQUE    70.00 %
5.a To accept the selection and return to the 
Actual Signal Display Mode.
 1 L -> 1242.0 rpm I
FREQ       45.00 Hz
T
ORQUE     70.00 %
POWER      75.00 %
5.b To cancel the selection and keep the 
original selection.
The selected keypad mode is entered.
 1 L -> 1242.0 rpm I
FREQ       45.00 Hz
C
URRENT    80.00 A
POWER      75.00 %
ACT
ENTER
ENTER
ACT
FUNC DRIVE
PAR