Fieldbus control
149
Communication profiles
The ACS800 Winder supports one communication profile based on CSA 2.8/3.0
communication profile.
Table 3 DataSet 1 Word 1 - Fieldbus Main Cmd Wd (Actual Signal 06.01)
Bit Name Description
0 DRIVE ENABLE See chapter Actual signals and parameters, parameter 16.01.
1 USER 2 MACRO SEL See chapter Actual signals and parameters, parameter 16.05.
2 Reserved
3 RUN CMD See chapter Actual signals and parameters, parameter 10.01.
4 REVERSE CMD See chapter Actual signals and parameters, parameter 10.02.
5 CONSTANT SPEED SEL See chapter Actual signals and parameters, parameter 12.01.
6 CONSTANT SPEED SEL See chapter Actual signals and parameters, parameter 12.01.
7 FAULT RESET CMD See chapter Actual signals and parameters, parameter 16.04.
8 INCHING SPEED SEL See chapter Actual signals and parameters, parameter 12.04.
9 PAYOUT SPEED SEL See chapter Actual signals and parameters, parameter 12.06.
10 REMOTE CMD
(Profibus Only)
11 RELAY OUTPUT 1
12 RELAY OUTPUT 2
13 RELAY OUTPUT 3
14 HEARTBEAT
15 Reserved