Start-up
3
Start-up
Chapter overview
The chapter instructs how to:
• complete the initial start-up.
• perform an identification run (ID Run) for the drive.
How to start-up
SAFETY
The start-up may only be carried out by a qualified electrician.
The safety instructions must be followed during the start-up procedure. See the
appropriate hardware manual for safety instructions.
Check the installation. See the installation checklist in the appropriate hardware/installation
manual.
Check that the starting of the motor does not cause any danger.
De-couple the driven machine if:
- There is a risk of damage in case of incorrect direction of rotation, or
- A Standard ID Run needs to be performed during the drive setup (see subsection How to
perform the ID Run on page 7).
POWER-UP
Apply mains power. The control panel first shows the panel
identification data …
CDP312 PANEL
Vx.xx
.......
…then the Identification Display of the drive …
ACS 800 xx kW
ID NUMBER 1
…and after a few seconds the panel enters the Actual Signal
Display.
The drive is now ready for the start-up.
1 -> 0.0 rpm O
F
REQ 0.00 Hz
CURRENT 0.00 A
POWER 0.00 %