Actual signals
Index Name Short Name FbEq Unit Range PB
01 ACTUAL SIGNALS
01.02 MOTOR SPEED FILT SPEED 200 = 1% rpm 2
01.03 FREQUENCY FREQ 1 = 1 Hz Hz 3
01.04 CURRENT CURRENT 10 = 1 A A 4
01.05 TORQUE TORQUE 10 = 1% % 5
01.06 POWER POWER 10 = 1% % 6
01.07 DC BUS VOLTAGE DC BUS V 1 = 1 VDC V 7
01.08 MAINS VOLTAGE MAINS V 1 = 1 VAC V 8
01.09 OUTPUT VOLTAGE OUT VOLT 1 = 1 VAC V 9
01.10 ACS800 TEMP ACS TEMP 1 = 1% % 10
01.14 OP HOUR COUNTER OP HOURS 1 = 1 hr h 14
01.15 KILOWATT HOURS KW HOURS 1 = 100 kWh kWh 15
01.16 APPL CODE DUTY APP DUTY 1 = 1% % 16
01.17 DI6-1 STATUS DI6-1 0…65535 (Decimal) 17
01.18 AI1 [V] AI1 [V] 1000 = 1 V V 18
01.19 AI2 [mA] AI2 [mA] 1000 = 1 mA mA 19
01.20 AI3 [mA] AI3 [mA] 1000 = 1 mA mA 20
01.21 RO3-1 STATUS RO3-1 0…65535 (Decimal) 21
01.22 AO1 [mA] AO1 [mA] 1000 = 1 mA mA 22
01.23 AO2 [mA] AO2 [mA] 1000 = 1 mA mA 23
01.28 AO3 [mA] AO3 [mA] 1000 = 1 mA mA 28
01.29 AO4 [mA] AO4 [mA] 1000 = 1 mA mA 29
01.35 MOTOR 1 TEMP M1 TEMP 1 = 1 °C °C 35
01.36 MOTOR 2 TEMP M2 TEMP 1 = 1 °C °C 36
01.37 MOTOR TEMP EST MOTOR TE 1 = 1 °C °C 37
01.38 AI5 [mA] AI5 [mA] 1000 = 1 mA mA 38
01.39 AI6 [mA] AI6 [mA] 1000 = 1 mA mA 39
01.40 DI7-12 STATUS DI7-12 0…65535 (Decimal) 40
01.41 RO4-7 STATUS RO4-7 0…65535 (Decimal) 41
01.43 MOTOR RUN-TIME M RUNTME 1 = 10 hr h 43
01.44 FAN ON-TIME FAN TIME 1 = 10 hr h 44
01.45 CTRL BOARD TEMP CTRL B T 1 = 1 °C °C 45
02 ACTUAL SIGNALS
02.01 SPEED REF 2 S REF 2 200 = 1% rpm 51
02.02 SPEED REF 3 S REF 3 200 = 1% rpm 52
02.03 SPEED REF 4 S REF 4 200 = 1% rpm 53
02.04 SPEED USED REF SPD USED 200 = 1% rpm 54
02.05 SPEED ESTIMATED SPEED ES 200 = 1% rpm 67
02.06 SPEED MEASURED SPEED ME 200 = 1% rpm 68
02.07 MOTOR TORQUE FILT TORQFILT 100 = 1% % 65
02.08 TORQ REF 1 T REF 1 100 = 1% % 58
02.09 TORQ REF 2 T REF 2 100 = 1% % 59
02.10 TORQ REF 3 T REF 3 100 = 1% % 60
02.11 TORQ REF 4 T REF 4 100 = 1% % 61
02.12 TORQ REF 5 T REF 5 100 = 1% % 62
02.13 TORQ USED REF T USED R 100 = 1% % 63
02.14 ACTUAL MTR FLUX ACT FLUX 100 = 1% % 64
02.15 ALARM WORD 1 ALARM W1 0…65535 (Decimal) 65
02.16 ALARM WORD 2 ALARM W2 0…65535 (Decimal) 66
02.17 ALARM WORD 3 ALARM W3 0…65535 (Decimal) 67
02.18 FAULT WORD 1 FAULT W1 0…65535 (Decimal) 68
02.19 FAULT WORD 2 FAULT W2 0…65535 (Decimal) 69
02.20 FAULT WORD 3 FAULT W3 0…65535 (Decimal) 70
02.21 SYSTEM FAULT SYS FLT 0…65535 (Decimal) 71
02.22 INT FAULT INFO INFO 0…65535 (Decimal) 72
02.23 LIMIT WORD 1 LIMIT W1 0…65535 (Decimal) 73

Table of Contents