Additional data: actual signals and parameters
177
02.24 MAIN CTRL WORD MAIN CW 0…65535 (Decimal) 74
02.25 FOLLOWER MCW FOLL MCW 0…65535 (Decimal) 75
02.26 MAIN STATUS WORD MAIN SW 0…65535 (Decimal) -
02.27 AUX STATUS WORD AUX SW 0…65535 (Decimal) -
02.28 AUX STATUS WORD 4 AUX SW4 0…65535 (Decimal) -
02.31 LATEST FAULT LAST FLT 0…65535 (Decimal) -
02.32 2.LATEST FAULT 2.FAULT 0…65535 (Decimal) -
02.33 3.LATEST FAULT 3.FAULT 0…65535 (Decimal) -
02.34 4.LATEST FAULT 4.FAULT 0…65535 (Decimal) -
02.35 5.LATEST FAULT 5.FAULT 0…65535 (Decimal) -
02.36 LATEST WARNING LAST WRN 0…65535 (Decimal) -
02.37 2.LATEST WARNING 2.WARN 0…65535 (Decimal) -
02.38 3.LATEST WARNING 3.WARN 0…65535 (Decimal) -
02.39 4.LATEST WARNING 4.WARN 0…65535 (Decimal) -
02.40 5.LATEST WARNING 5.WARN 0…65535 (Decimal) -
02.41 LIMIT WORD INV LIM WD INV 0…65535 (Decimal) -
02.42 MTR ACCELERATION MTR ACC 1 = 1 rpm/s rpm/s -
03 ACTUAL SIGNALS
03.01 DRAW SETPOINT DRAW SP 100 = 1% % 76
03.02 TOTAL DRAW TRIM TTL SPNT 100 = 1% % 77
03.03 DANCER LOAD SETPT DAN LD S 10 = 1% % 78
03.04 DANCER LOAD REF DAN LD R 10 = 1% % 79
03.05 DANCER REG OUTPUT DAN REG 10 = 1% % 80
03.06 DANCER POSITION DAN POS 10 = 1 mm
10 = 1 inch
mm
inch
81
03.07 TENSION SETPOINT TEN SP 10 = 1 N
10 = 1 lb
N
lb
82
03.08 TENSION REFERENCE TEN REF 10 = 1 N
10 = 1 lb
N
lb
83
03.09 TENSION REG OUTPT TEN REG 10 = 1% % 84
03.10 TENSION ACTUAL TEN ACT 10 = 1 N
10 = 1 lb
N
lb
85
03.11 TEN CALC TORQ REF CALC TRQ 1 = 1 Nm
1 = 1 lbft
Nm
lbft
86
03.12 CALC TTL INERTIA INERTIA 1 = 1 kgm
2
1 = 1 lbft
2
kgm
2
lbft
2
87
03.13 ROLL DIAMETER ROLL DIA 10 = 1 mm
10 = 1 inch
mm
inch
88
03.14 % FULL ROLL % FUL ROL 10 = 1% % 89
03.15 PACK STATUS BITS STATU BIT 0…65535 (Decimal) 90
03.16 PSEUDO SPD OUT PS SPD O 200 = 1% rpm 91
03.17 PSEUDO SPD IN PS SPD I 200 = 1% rpm 92
03.18 FRICTION COMP FRICTION 1 = 1 Nm
1 = 1 lbft
Nm
lbft
93
03.19 PSEUDO OUT SCLD PSO SCLD 1 = 1 94
06 CH0 DATASETS IN
06.01 DATASET 1 WORD 1 DS1 WD1 - 32768…32767 -
06.02 DATASET 1 WORD 2 DS1 WD2 - 32768…32767 -
06.03 DATASET 1 WORD 3 DS1 WD3 - 32768…32767 -
06.04 DATASET 2 WORD 1 DS3 WD1 - 32768…32767 -
06.04 DATASET 2 WORD 2 DS3 WD2 - 32768…32767 -
06.05 DATASET 2 WORD 3 DS3 WD3 - 32768…32767 -
06.07 DATASET 3 WORD 1 DS5 WD1 - 32768…32767 -
06.08 DATASET 3 WORD 2 DS5 WD2 - 32768…32767 -
06.09 DATASET 3 WORD 3 DS5 WD3 - 32768…32767 -
09 ACTUAL SIGNALS
09.01 AI1 SCALED AI1 SCAL 2000 = 1 V 0…20000 -