NoteAction
Water temperature: ambientRinse thoroughly with water to remove the disin-
fection.
11
Wipe the surface dry with lint free cloth.12
If user tools are removed from the robot flange
before the cleaning, then, after cleaning,
• Make sure no residues left on the tool
flange or screw holes before reinstall the
tools or any other accessories to the flange.
13
Wipe down procedure
NoteAction
Before cleaning,
• Make sure no spraying or ejecting of any
detergents, disinfectants and water to the
robot surfaces during the cleaning.
1
Use the lint free cloth to remove soils or any other
contaminant from the to-be-cleaned surfaces.
2
Make sure no visible residues left.
Disinfectant: DRYSAN
TM
DUO,
concentration (v/v) 100 %
Spray disinfectant DRYSAN
TM
DUO on robot
surfaces.
3
Wait 2-3 minutes for disinfectant volatilization and
then wipe the robot with lint free cloth.
4