NoteAction
Apply a little grease to the sealing when
replacing the radial sealing and wipe clean
after the replacement.
4
Fit the radial sealing into the housing ex-
tender unit.
5
Axis-4 sealing assembly tool set:
3HAC049699-001
xx1400000436
Fit the circular part of the radial sealing
assembly tool against the radial sealing.
6
Fit the tool plate to the other side of the
housing extender unit with the six screws
M6X50.
7
xx1400000437
Screw the screws, little by little, to press
the sealing into place.
8
Remove the assembly tool.9
Check that the sealing is undamaged and
properly fitted.
10
Refit both the axis-4 mechanical stop and
the axis-4 FPC unit to the housing extender
unit.
11
Continues on next page
474 Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.4.7 Replacing the axis-4 mechanical stop
Continued