2.6 Robot in hot environments
2.6.1 Start of robot in hot environments
Introduction
This procedure describes how to start the robot in a hot environment. This
procedure must be performed the first time the robot is started in a hot environment
or if it has not been used for some time in a hot environment.
There is a possibility that some overpressure has been built up in the system. This
overpressure must be released before starting up the robot.
Releasing overpressure in gearboxes
Use this procedure before the start of the robot in a hot environment to release
potential overpressure being built up in gearboxes.
NoteAction
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot work-
ing area.
1
CAUTION
Before approaching the potentially hot robot
component, observe the safety information
in section Hot parts may cause burns on
page 34.
2
Note
Before opening the oil plug, make certain that
the oil plug is above the oil level. Place the
robot accordingly.
3
Tip
Hold a cloth or some paper over the oil
plug while opening it to prevent surplus
oil causing burns or other injuries.
Open oil plug filling very carefully!
Note
Open the oil plug just enough for the overpres-
sure to be released.
4
Let the overpressure leave the gearbox.5
Refit the oil plug.6
Continue releasing the overpressure on all
gearboxes.
7
102 Product manual - IRB 2600
3HAC035504-001 Revision: Q
© Copyright 2009-2018 ABB. All rights reserved.
2 Installation and commissioning
2.6.1 Start of robot in hot environments

Table of Contents

Related product manuals