Remove motor axis 5 by unscrewing its at-
tachment screws.
21
Parts:
A: Upper arm tube
B: Motor axis 5
Refitting motor axis 5
Use this procedure to refit motor axis 5.
InformationAction
Place motor axis 5 in the upper arm tube.1
A
B
xx1000000937
Tighten the attachment screws just enough
to still be able to move the motor.
2
Parts:
A: Upper arm tube
B: Motor axis 5
Adjust the play by finding the smallest play.3
Tightening torque: 10 Nm.Secure the motor with its attachment
screws.
4
Lift the upper arm tube to the robot.5
Continues on next page