InformationAction
Note
If axis 4 is not running correctly the spiral
of the cable harness must be refitted.
Check that the cable harness is fitted cor-
rectly by releasing the brakes on the axis-
4 motor and manually moving axis 4 very
carefully all the way to each end position.
CAUTION
Too much force when turning axis 4 can
result in damage to the cable harness!
13
xx1000001003
Apply flange sealant Loctite 574 on the
surface B, shown in the figure.
Note
Do not apply flange sealant on the surfaces
where Sikaflex 521FC shall be applied!
See figure!
14
Parts:
A Surface where Sikaflex 521FC shall
be applied
B Surface where Loctite 574 shall be
applied.
Tightening torque: 35 Nm.Secure the upper arm tube with its attach-
ment screws.
15
See section
Refitting the wrist on page 348
Refit the wrist.16
Continues on next page
Product manual - IRB 2600 231
3HAC035504-001 Revision: Q
© Copyright 2009-2018 ABB. All rights reserved.
4 Repair
4.3.3 Replacing the cable harness in the upper arm - IRB 2600ID
Continued