Periodic check of the calibration tool
If including the calibration tool in a local periodic check system, the following
measures should be checked.
Outer diameter within Ø12g4 mm, Ø8g4 mm or Ø6g5 mm (depending on
calibration tool size).
Straightness within 0.005 mm.
xx1500000951
Outer diameterA
Product manual - IRB 2600 407
3HAC035504-001 Revision: Q
© Copyright 2009-2018 ABB. All rights reserved.
5 Calibration
5.4.2 Calibration tools for Axis Calibration
Continued