Defining the parameter in the IRC5 software
The value of the system parameters that define the mounting angle must be
redefined when changing the mounting angle of the robot. The parameters belong
to the type Robot, in the topic Motion.
How to calculate a new value is detailed in Mounting angles and values on page 65.
The system parameters are described in Technical reference manual - System
parameters.
The system parameters are redefined in the Configuration Editor, in RobotStudio
or on the FlexPendant.
Product manual - IRB 2600 67
3HAC035504-001 Revision: Q
© Copyright 2009-2018 ABB. All rights reserved.
2 Installation and commissioning
2.3.3 Setting the system parameters for a suspended or tilted robot
Continued