Note/IllustrationAction
For the Ethernet extension switch (op-
tion):
K2.X2 - K4.X8, A2.X1
K4.X7 - K5.1.X5
K4.X6 - A2.X4
For the Connected Services Gateway:
K7.X1 - K2.X3
i
K7.X2 - A2.X5
Note
The connector K7.X2 is locked; grab the
connector, push it in to release it and
then remove the connector.
For the main computer:
K2.X8 - A2.X6
K2.X2 - K4.X8, A2.X1
K2.X12 - A2.K3.X6, A2.K3.X7
K6.X2 - A2.X9
A2.X5 - K7.X2
A2.X4 - K4.X6/K5.1.X5
Note
If the Ethernet extension switch is
installed, connect and disconnect
the connector A2.X4 to/from
K4.X6.
If the Ethernet extension switch is
not installed, connect and discon-
nect the connector A2.X4 to/from
K5.1.X5.
xx1900001877
Remove the screws holding the main
computer.
2
Continues on next page
124 Product manual - OmniCore C90XT
3HAC073706-001 Revision: D
© Copyright 2020-2021 ABB. All rights reserved.
3 Installation and commissioning
3.7.6 Installing the fieldbus master
Continued