Removing the robot signal exchange proxy
Note/IllustrationAction
Disconnect:
K2.X8 - A2.X6
(option): K2.X2 - K4.X8, A2.X1
K2.X12 - A2.K3.X6, A2.K3.X7
K2.X10 - A1.X13
K2.X21 - TempSensor (G3.TEMP)
K2.X4 - A1.X9
K2.X3 - K6.X1, A2.K3.X1, K5.1.X4,
K7.X1
K2.X1 - T2.X2
K2.X17 - G3.X1, G1.X2
K2.X6, K2.X11 - A1.X2
K2.X7, K2.X22 - Harn. LV robot
power (X1)
K2.X9 & X13 - FlexPendant (X4)
1
xx1900002339
Remove the mating connectors by
loosening their attachment screws.
2
xx1900001495
Pull the cable ties out from the locking
holes.
3
Continues on next page
194 Product manual - OmniCore C90XT
3HAC073706-001 Revision: D
© Copyright 2020-2021 ABB. All rights reserved.
5 Repair
5.2.4 Replacing the robot signal exchange proxy
Continued