Note/IllustrationAction
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 43.
2
xx1900002331
Hook up the Connected Services Gate-
way to the bracket and push carefully into
position.
Note
During the installation, the gap between
the lower surface of the Connected Ser-
vices Gateway and the upper surface of
the main computer should be zero.
3
Reconnect:
• K7.X1 - K2.X3
i
• K7.X2 - A2.X5
4
i
For Connected Services Gateway wired, there is no power cable.
Reconnecting the antenna
Note/IllustrationAction
Refitting the cable grommet assembly on
page 317.
Insert the cable from the cable grommet.1
Refit the cable in the cabinet according
to the record during the disassembly.
2
Continues on next page
206 Product manual - OmniCore C90XT
3HAC073706-001 Revision: D
© Copyright 2020-2021 ABB. All rights reserved.
5 Repair
5.2.6 Replacing the Connected Services Gateway
Continued