SignificanceDescription
Shows the status of Ethernet communication between the drive unit and
the power unit.
Ethernet LEDs
Green:
Off: 10 Mbps data rate is selected.
On: 100 Mbps data rate is selected.
Yellow:
Flashing: The two units are communicating on the Ethernet channel.
Steady: A LAN link is established.
Off: A LAN link is not established.
The status indicator LED can be used to identify the following status
during startup/power on:
1 Red, steady: Default when power is available.
2 Red, flashing: Power is on, self-test is ongoing, operating system
is loading.
3 Green, flashing: Application is loaded and waiting for communica-
tion.
4 Green, steady: Drive unit is operational.
If the LED does not turn steady green after 30-60 sec, the status indicator
LED can be used to identify the following issues:
No color: Power to the drive unit is missing.
Red, steady: Internal error.
Red, flashing: Firmware error or self-test failure.
Green, flashing: Communication error to another module.
Drive unit status
LED