Maintenance 113
Replacing the LCL filter cooling fan (R8i, 2 × R8i, 3 × R8i)
WARNING! Obey the safety instructions, page 11. If you ignore the instructions,
physical injury or death, or damage to the equipment can occur.
1. Stop the inverter and do the steps in section Precautions before electrical work on
page 12 before you start the work.
2. Open the LCL filter cubicle door.
3. Disconnect the fan wiring plug.
4. Undo the screw of the fan fastening clip.
5. Pull the fan out.
6. Install a new fan in reverse order.