ABB RET670 Applications Manual

ABB RET670
888 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
Table of contents
Section 1 Introduction..........................................................................15
Introduction to the application manual....................................................15
About the complete set of manuals for an IED..................................15
About the application manual............................................................16
Intended audience.............................................................................17
Related documents............................................................................17
Revision notes...................................................................................17
Section 2 Requirements......................................................................19
Current transformer requirements..........................................................19
Current transformer classification......................................................19
Conditions..........................................................................................20
Fault current.......................................................................................21
Secondary wire resistance and additional load.................................21
General current transformer requirements........................................22
Rated equivalent secondary e.m.f. requirements..............................22
Transformer differential protection................................................22
Distance protection.......................................................................23
Restricted ground fault protection (low impedance
differential)....................................................................................24
Current transformer requirements for CTs according to other
standards...........................................................................................27
Current transformers according to IEC 60044-1,
class P, PR...................................................................................27
Current transformers according to IEC 60044-1, class PX,
IEC 60044-6, class TPS (and old British Standard, class X)........28
Current transformers according to ANSI/IEEE.............................28
Voltage transformer requirements..........................................................29
SNTP server requirements.....................................................................29
IEC 61850-9-2LE Merging unit requirements ........................................30
Section 3 IED application....................................................................31
General IED application..........................................................................31
Analog inputs..........................................................................................33
Introduction........................................................................................33
Setting guidelines..............................................................................33
Setting of the phase reference channel........................................33
Table of contents
1
Application manual

Table of Contents

Other manuals for ABB RET670

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB RET670 and is the answer not in the manual?

ABB RET670 Specifications

General IconGeneral
Rated Frequency50/60 Hz
InputsAnalog and binary inputs
ApplicationProtection of power systems
Communication ProtocolsIEC 61850, DNP3, Modbus
Operating Temperature Range-25°C to +55°C
MountingRack mounted
Number of Binary InputsUp to 48
Number of Binary Outputs32
Protection FunctionsOvercurrent Protection
OutputsBinary outputs
EnclosureIP 54
TypeLine Differential Protection
Number of Analog Inputs24

Related product manuals