61179641L4-5B 5-95
Table 5-62. T1 Provisioning Menu Options
Option Description T1 Function
1 Type This field displays the T1 circuit type.
2 Framing This field displays the framing setting for the T1 circuit.
Settings include the following:
•SF
•ESF
3 Line Code This field displays the line code setting for the T1 circuit.
Settings include the following:
•B8ZS
•AMI
4 Line Build Out This field displays the line build out settings based upon
the Type setting. Settings include the following:
Type = DSX
•0-133 feet
• 133-266 feet
• 266-399 feet
• 399-533 feet
• 533-655 feet
Type = T1
•0 dB
• –7.5 dB
• –15 dB
• –22.5 dB

Table of Contents