2.3. Hazards from lithium-ion batteries
DLT-V83 industrial PCs with integrated UPS (optional) are equipped with lithium-ion
batteries in the cable cover of the device. Lithium-ion batteries are chemical stores of
energy which can lead to personal injury or physical damage if they are stored or
handled improperly, for example due to:
− Mechanical damage to the lithium-ion batteries.
− Thermal loading of the lithium-ion batteries.
− Overloading of the lithium-ion batteries.
− Deep-discharge of the lithium-ion batteries.
Specifications for DLT-V83 with integrated UPS and lithium-ion batteries
Storage temperature -20 to +60 °C
Operating temperature -10 to +50 °C
Charging temperature 0 to +45 °C (internal device temperature)
Relative humidity 10% to 90% at 40 °C relative humidity, noncondensing
Mechanical vibration
and shock resistance
Class 5M3 according to EN 60721-3-5
US Highway Truck according to MIL-STD 810F
Maximum output power 35 W
Input voltage 12 V
Output voltage Typically 12 V
Battery voltage 7.2 V
Battery capacity 2200 mAh
Handling
The optional UPS cable cover of the DLT-V83 contains lithium-ion batteries.
Handle it carefully.
Observe the specific IP protection class.
Observe the correct installation of the cable cover.
Only use the DLT-V83 within the specified temperature range and permitted
humidity.
Do not subject it to strong impacts and vibrations that exceed what is specified by
the class 5M3 (DIN EN 60721-3-5).
When working on the cable cover with lithium-ion batteries, you must remove
wristwatches, rings or other metal objects.
Use only tools with insulated handles.
Do not damage the cable cover with lithium-ion batteries; do not drill through and
do not crush or drop.