Power supply units, pin assignment, power supply
Page 90 of 178 DLT-V83 Series Manual V1.31 Advantech-DLoG
Power supply
DC power pack
12/24/48 VDC
(wide-range power
supply unit)
60 W / 80 W internal
Type DC-16
12/24/48 VDC nominal
Galvanically isolated
Withstands bursts up to 2 kV
Full output power of the 12/24/48 VDC power supply unit
for 20 seconds each:
For 6 V: 40 W
For 9 V: 60 W
Rising in linear fashion between the above
Voltage range 9 to 60 VDC
Bridged power failures Typically 2 ms at 12 V
Typically 10 ms at 24 V
Typically 40 ms at 48 V
Maximum output power 60 W (+10 to +70 °C internal device temperature);
or 80 W (-30 to +10 °C internal device temperature)
Nominal current 8.4 A
Connection to SELV
circuit only
The SELV circuit is a secondary circuit that is designed
and protected so that its voltages will not exceed a safe
value both when operating correctly or if a single error
occurs.
Power consumption
DLT-V8310 Typically 25 W; standby typically 1 W
DLT-V8312 Typically 30 W; standby typically 1 W
DLT-V8315 Typically 30 W; standby typically 1 W
Power supply unit fuses
Power supply unit Fuse type Example
DC-16 5 x 20 mm T
12.5 A
H / 250 V
Schurter 0001.2515
Siba 179200.12,5
or similar produced by other manufacturers
The symbol for the fuse is FA.
You will find the exact position on the sticker located on the connection plate of the
DLT-V83.