ACCEPTANCE TESTING
7-55
Table 7-22 Internal FM deviation and distortion tests at 100 kHz deviation
FM deviation Distortion
Carrier
frequency
(MHz)
FM deviation
min. (kHz)
Result (kHz) FM deviation
max. (kHz)
Distortion (%) Result (%)
10 96 _______ 104 <3% _______
10.144 96 _______ 104 <3% _______
10.292 96 _______ 104 <3% _______
10.441 96 _______ 104 <3% _______
10.592 96 _______ 104 <3% _______
10.746 96 _______ 104 <3% _______
10.901 96 _______ 104 <3% _______
11.059 96 _______ 104 <3% _______
11.22 96 _______ 104 <3% _______
11.382 96 _______ 104 <3% _______
11.547 96 _______ 104 <3% _______
11.714 96 _______ 104 <3% _______
11.884 96 _______ 104 <3% _______
12.056 96 _______ 104 <3% _______
12.23 96 _______ 104 <3% _______
12.5 96 _______ 104 <3% _______
12.587 96 _______ 104 <3% _______
12.77 96 _______ 104 <3% _______
12.995 96 _______ 104 <3% _______
13.143 96 _______ 104 <3% _______
13.333 96 _______ 104 <3% _______
Table 7-23 FM scale shape tests at 15 MHz carrier
FM deviation (kHz) FM deviation
min. (kHz)
Result (kHz) FM deviation
max. (kHz)
100 96 _______ 104
71 68.16 _______ 73.84
56 53.76 _______ 58.24
44 42.24 _______ 45.76
34 32.64 _______ 35.36
27 25.92 _______ 28.08
21 20.16 _______ 21.84
16 15.36 _______ 16.64
13 12.48 _______ 13.52
11 10.56 _______ 11.44
10 9.6 _______ 10.4
1 0.96 _______ 1.04
0.1 0.096 _______ 0.104