REMOTE OPERATION POWER COMMANDS
4-151
[SOURce]:POWer[:LEVel][:IMMediate][:AMPLitude]:OFFSet:LOSS
Description: Sets the external system loss value for power offset.
Note that gain, attenuation and system loss are added together to give the overall offset.
Actual RF output power = displayed RF level gain value + attenuation value +
system loss value.
Parameters: <numeric_value>
Valid values: <NRf>(dB) | MINimum | MAXimum
*RST sets: 0 dB
[SOURce]:POWer[:LEVel][:IMMediate][:AMPLitude]:OFFSet:LOSS?
Description: Returns the external system loss value for power offset.
Parameters: None
Response: <NR2>
Returned values: Loss level (dB)
[SOURce]:POWer[:LEVel][:IMMediate][:AMPLitude]:OFFSet:STATe
Description: Sets the carrier level offset on or off.
Parameters: <Boolean>
Valid values: OFF | ON | 0 | 1
*RST sets: OFF
[SOURce]:POWer[:LEVel][:IMMediate][:AMPLitude]:OFFSet:STATe?
Description: Queries whether the carrier level offset is off (0) or on (1).
Parameters: None
Response: <Boolean>
Returned values: 0 | 1