1-10 Agilent 4155C/4156C User’s Guide Vol.1, Edition 11
Introducing the 4155C/4156C
Front View of the 4155C/4156C
Standby indicator
This indicator lights when the 4155C/4156C is standby enabled, which means
that the channels that are standby enabled (STBY ON) will return to the standby
state after the measurement is finished.
IBASIC key group
IBASIC keys control the IBASIC program execution.
Run key Starts the IBASIC program that is in memory. The indicator
is on during program execution.
Pause key Pauses the IBASIC program execution.
Display key Toggles between the IBASIC screen and measurement
screen.
Run indicator
When an IBASIC program is running, this indicator lights.
ENTRY key group
You enter or modify data such as output values, comments, and variable names.
Character keys Are used to enter alphanumeric and special characters.
Enter key After you enter desired characters into the data entry field,
press this key. The characters are entered at the field pointer
location. Also, you can use the green key to calculate the
value of the data entry field. For example, if you press
4 * 6
green key
and Enter key, the result (24) appears.
Blue key Changes entry mode to blue-key shift mode, and lights the
indicator. In this mode, you can enter the blue characters
that are printed above the keys. Pressing blue key again
changes to normal mode. Indicator turns off.
Green key Changes entry mode to green-key shift mode. This mode is
effective for the next pressed key, then changes back to
normal mode.
Edit keys Are used to edit the characters in the data entry field.
User File keys Are used to operate quickly on a file in diskette, internal
memory or a directory on a NFS server. Pressing
Save key
moves into the filer's SAVE function, and pressing
Get key
moves into the filer's GET function.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 41501B and is the answer not in the manual?

Agilent Technologies 41501B Specifications

General IconGeneral
BrandAgilent Technologies
Model41501B
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals