30 Maintaining Your GC
4 Maintaining Capillary Columns
Consumables and Parts for Columns
See the Agilent catalog for consumables and supplies for a
more complete listing, or visit the Agilent Web site for the latest
information (www.agilent.com/chem/supplies).
Table 3 Nuts, ferrules, and hardware for capillary columns
Column id (mm) Description Typical use Part number/quantity
.530 Ferrule, Vespel/graphite,
0.8-mm id
0.45-mm and 0.53-mm capillary
columns
5062-3512 (10/pk)
Ferrule, graphite, 1.0-mm id 0.53-mm capillary columns 5080-8773 (10/pk)
Ferrule, graphite, 0.8-mm id 0.53-mm capillary columns 500-2118 (10/pk)
Column nut, finger-tight (for
0.53-mm columns)
Connect column to inlet or detector 5020-8293
.320 Ferrule, Vespel/graphite,
0.5-mm id
0.32-mm capillary columns 5062-3514 (10/pk)
Ferrule, graphite, 0.5-mm id 0.1-mm, 0.2-mm, 0.25-mm, and
0.32-mm capillary columns
5080-8853 (10/pk)
Column nut, finger-tight (for
.100- to .320-mm columns)
Connect column to inlet or detector 5020-8292
.250 Ferrule, Vespel/graphite,
0.4-mm id
0.1-mm, 0.2-mm, and 0.25-mm
capillary columns
5181-3323 (10/pk)
Ferrule, graphite, 0.5-mm id 0.1-mm, 0.2-mm, 0.25-mm, and
0.32-mm capillary columns
5080-8853 (10/pk)
Column nut, finger-tight (for
.100- to .320-mm columns)
Connect column to inlet or detector 5020-8292
.100 and .200 Ferrule, Vespel/graphite,
0.37-mm id
0.1-mm and 0.2-mm capillary
columns
5062-3516 (10/pk)
Ferrule, Vespel/graphite,
0.4-mm id
0.1-mm, 0.2-mm, and 0.25-mm
capillary columns
5181-3323 (10/pk)
Ferrule, graphite, 0.5-mm id 0.1-mm, 0.2-mm, 0.25-mm, and
0.32-mm capillary columns
5080-8853 (10/pk)
Ferrule, graphite, 0.4-mm id 500-2114 (10/pk)
Column nut, finger-tight (for
.100- to .320-mm columns)
Connect column to inlet or detector 5020-8292
All Ferrule, no-hole Testing 5181-3308 (10/pk)
Capillary column blanking nut Testing–use with any ferrule 5020-8294
Column nut, universal Connect column to inlet or detector 5181-8830 (2/pk)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies Agilent 7890 Series and is the answer not in the manual?

Agilent Technologies Agilent 7890 Series Specifications

General IconGeneral
BrandAgilent Technologies
ModelAgilent 7890 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals