EasyManuals Logo

Agilent Technologies auroraSonata User Manual

Agilent Technologies auroraSonata
336 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #116 background imageLoading...
Page #116 background image
aurora
Sonata
Hand Held ISDN Tester—User Guide
4-6 427869
Simulation on the U interface
On the U interface, you can use aurora
Sonata
to emulate
Terminal Equipment (a TE) or a Line Termination (LT) device.
Emulating a TE on the U interface
When aurora
Sonata
emulates a TE on the U interface, it operates
as both the NT1 and the TE. You would use this:
to check the interface during line installation
to find out whether a suspected fault is on the
U interface side of the NT
aurora
Sonata
can emulate a TE on the U interface using 2B1Q,
4B3T or Up0 line coding, when the appropriate module is
fitted.
Emulating an LT on the U interface
You would use aurora
Sonata
to emulate an LT:
to test towards the NT (check the local loop)
to test the line from the exchange end
aurora
Sonata
can emulate an LT on the U interface using 2B1Q,
4B3T or Up0 line coding, when the appropriate modules are
fitted.
‘NT replacement’ test
When your aurora
Sonata
is fitted with one S and one U interface
module, you can disconnect the NT and replace it with
aurora
Sonata
. This allows you to test whether the NT is faulty.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies auroraSonata and is the answer not in the manual?

Agilent Technologies auroraSonata Specifications

General IconGeneral
BrandAgilent Technologies
ModelauroraSonata
CategoryTest Equipment
LanguageEnglish

Related product manuals