Issue 2 - 07/00 4-9
Testing in Simulation Mode - Section 1
You can test fixed links with BRI or PRI access, provided the
appropriate interface module is fitted. For Basic Rate you can
test fixed links at the S interface or at the U interface using
2B1Q, 4B3T or Up0 line coding. There are two methods:
replacing the NT with an aurora
Sonata
connecting aurora
Sonata
and another device (e.g. a
Agilent Technologies ISDN tester) at either end
of the link, with one emulating a TE and the
other an NT
2 Notes:
Because there is no D channel protocol, there is no way
to tell when aurora
Sonata
receives a fixed link call. Both
ends of the link must be set up for fixed link operation.
When aurora
Sonata
is set up to test fixed links you do not
have the option to use ‘any’ B channel (Bx) for the test.
For details on channel selection, see Chapter 3 section 2.
Introducing the ISDN Test Suite
aurora
Sonata
s ISDN Test Suite offers you a quick and easy way
of performing the most common tests on an ISDN link.
If CorNet-T is selected you cannot use the Test Suite.
Displaying the ISDN Test Suite
-1-
Either:
in the top level menu, press the Test
function key
from the main Simulate menu, select ISDN
Test Suite

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies auroraSonata and is the answer not in the manual?

Agilent Technologies auroraSonata Specifications

General IconGeneral
BrandAgilent Technologies
ModelauroraSonata
CategoryTest Equipment
LanguageEnglish

Related product manuals